Brand Name : ASSEN
Model Number : ACP-3
Certification : CE ISO
MOQ : 1
Price : 2300
Payment Terms : T/T, L/C
Supply Ability : 100 sets per month
Delivery Time : 7 days
Packaging Details : wooden case
name : current transformer tester
Application:
ACP portable Current transformer analyzer is mainly used for field or lab testing, it can finish the
measurements (M) and protection (P) class CT, PT, and TYP class CT.
Adopt 7-inch touch TFT LCD, self-equipped mini type printer
supporting field printing; supporting to use USB flash disk to dump
data. The CT PT Analyzer is the most complete and easy-to-use
testing system for protection and metering CTs according to IEEE
and IEC standards.
Tests for current transformer:
1.Excitation curve and parameters test
2.Turns ratio test
3.Ratio and phase error test
4.Polarity mark check
5.Coil resistance measurement
6.Secondary loop burden measurement
7.Error line curve test for protection CT
8.Transient CT parameters test
9.CT nameplate guess
10.Saturation hysteresis loop curve measurement
Tests for voltage transformer:
1) Turns ratio test
2) Ratio error and phase angle error test
3) Polarity test
4) Secondary burden test
5) Winding resistance test
ACP Current Transformer Tester's Specification:
No. | Item Name | ACP Current Transformer and Voltage Transformer CT PT Analyzer |
1 | Test standards | IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13 |
2 | Power supply | AC220V±10%,50Hz/60Hz±10% |
3 | Power output | 0.1~125V (AC) |
4 | Current output | 0.001~5A(RMS) |
5 | Power output | 300VA |
6 | Max. knee voltage measurement | 45kv |
7 | Current measurement range | 0~10A (automatically change range in 0.1/0.4/2/10A) |
8 | Current measurement error | <±0.1%+0.01%FS |
9 | Voltage measurement range | 0~200 V (automatically change range in 1V/10V/70V/200V) |
10 | Voltage measurement error | < ±0.1%+0.01%FS |
11 | Turns ratio measurement range | 1~30000; 1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2% |
12 | Phase measurement | error: ±2min,resolution:0.01min |
13 | Coil resistance measurement | Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm) Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ |
14 | Temperature measurement | -50~100 Celsius degree, error<3 Celsius degree |
15 | CT Secondary burden | Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm) Error<0.2%RDG+0.02%FS Maximum resolution 0.001ohm |
16 | PT Secondary burden | Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm) Error<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm |
17 | PT ratio measurement | Range: 1~30000 1~5000 error<0.2% 5000~30000 error<0.5% |
18 | Saved data groups | >1000groups |
19 | Work condition | Temperature: -10℃-50℃, moist: ≤90% |
20 | Size | 485mm*356mm*183mm |
21 | Weight | <15Kg |
Please contact:ASSEN Email:sales@assenpe.com Whatsapp:+86-15223801122 https://www.assenpe.com https://www.oilrecondition.com
![]() |